OPAL-105 Aldehyde and Alcohol Analysis System

Description

Application & Engineering Guide
Hydrate Inhibitors (MEG/MeOH) & Biocide Control
Explore rapid field testing methods for methanol, MEG, THPS, and glutaraldehyde residuals.

The OPAL-105 Aldehyde and Alcohol Analysis System is a precision benchtop Raman spectrometer engineered for rapid, quantitative measurement of simple aldehydes, alcohols, biocides, and hydrate inhibitors in oilfield waters, gas gathering lines, and industrial chemical processes. Utilizing solid-state Quantitative Raman Spectroscopy (QRS), the OPAL-105 provides laboratory-grade molecular quantification down to ppm levels directly on-site—eliminating hazardous derivatization steps, gas chromatography bottlenecks, and toxic colorimetric reagent kits.

Analytical Scope & Target Applications
  • Oilfield Biocide Monitoring: Rapid quantification of active glutaraldehyde and tetrakis(hydroxymethyl)phosphonium sulfate (THPS) in fracturing fluids, waterflood operations, and produced water systems.
  • Gas Hydrate Inhibition: Direct measurement of methanol (CH3OH) and monoethylene glycol (MEG) in raw natural gas liquids and pipeline condensates.
  • Formaldehyde Speciation: Accurate ppm-level detection of free formaldehyde residuals in H2S scavenger applications and industrial resins.
  • Ketone Analysis (Optional): Expanded method capabilities available for acetone and methyl isobutyl ketone (MIBK) in industrial solvent streams.
  • Interference Resistance: High tolerance to salinity, dissolved solids, and background hydrocarbon carryover in oilfield waters.
System Package (Standard Bill of Materials)
  • OPAL Benchtop Spectrometer: Solid-state Raman optical measurement unit with enclosed sample measurement port.
  • Universal AC Power Adapter: 100–240 VAC, 50/60 Hz power supply with standard IEC power cord.
  • USB Data Interface Cable: High-speed shielded connection to host PC or laptop.
  • OndaVia Raman Controller Software: Instrument communication, automated aldehyde/alcohol quantification, and reporting license.
  • Calibration Verification Standard: Reusable solid-state optical standard for routine QA/QC verification.
  • Documentation: Operating manual, factory certificate of calibration, and quick-start guide.
Technical Specifications
Physical Dimensions 6.0″ (W) × 5.0″ (D) × 3.0″ (H) [15.2 cm × 12.7 cm × 7.6 cm]
Instrument Weight 1.4 lbs (0.64 kg) — Ultra-compact benchtop footprint
Target Analytes Formaldehyde, Glutaraldehyde, Methanol, Monoethylene Glycol (MEG), THPS, Acetone, MIBK
Analytical Range Ppm-level to percentage-level (application-configured)
Analysis Cycle Time < 10 minutes (rapid pushbutton test cycle)
Sample Volume Required < 2.0 mL per measurement run
Optical Measurement Engine Solid-state Quantitative Raman Spectrometer (QRS)
Power Requirements Universal AC Adapter: 100–240 VAC, 50/60 Hz, 1.5A Max
System Interface USB 2.0 / 3.0; Windows 10/11 operating system compatible
Calibration Maintenance Factory pre-calibrated; verified via included solid-state reference standard
Consumable Compatibility OndaVia Glutaraldehyde Kits (Part # OV-PP-B023) and Aldehyde/Alcohol Microfluidic Cartridges

Consumables and Labware: Application-specific single-use microfluidic analysis cartridges (Part # OV-PP-B023, etc.) and precision micropipettes are supplied separately based on facility testing schedules.

Produced Water & Chemical Matrix Evaluation

Verify limit-of-detection and matrix compatibility for your chemical dosing program. Submit a 50 mL fluid sample for full laboratory Raman spectral screening and feasibility reporting within 48 hours.


Request Sample Evaluation Protocol →

Additional information

Weight 1.4 lbs
Dimensions 6 × 5 × 3 in
Model

Formaldehyde Model, Methanol Model

Brand

OndaVia, Opal