Methanol Analysis Kit

Price range: $165.00 through $444.00

Product total
Options total
Grand total

Description


Technical Application Guide

Gas Hydrate Inhibition & Methanol Flow Assurance Control

Learn how rapid on-site methanol quantification prevents subsea hydrate plugs, optimizes chemical injection economics, and protects catalysts.

Methanol ($CH_3OH$) is the predominant thermodynamic hydrate inhibitor (THI) injected into subsea tiebacks, gathering networks, and deepwater flowlines to prevent gas hydrate blockages. Tracking residual methanol concentration in produced water is critical to ensure hydrate protection while avoiding excessive chemical consumption or refinery penalties.

Hydrate Inhibition & Flow Assurance Optimization

Over-injecting methanol leads to high operating expenses and causes methanol carryover into refinery crude slates, poisoning hydrotreating catalysts. Real-time optical testing gives offshore operators the immediate data needed to optimize dosing.

Fast On-Site Spectroscopy vs. Laboratory Delays

The OndaVia Methanol Analysis Kit (Analyte Code: B036) provides fast, pushbutton optical measurement from ppm to 100% concentrations directly in the field.

Specification Parameter Consumable Kit Details
Target Chemical Analyte Methanol (CAS 67-56-1)
Analyte Number B036
Analytical Methodology Quantitative Raman Spectroscopy (QRS)
Analysis Turnaround Under 5 minutes per test cycle
Packaging Format & Yield 10 tests per box
Calibration Architecture Factory pre-calibrated per production lot; zero toxic liquid standard preparation
Storage & Shelf Life Store at room temperature; 12-month shelf life from date of manufacture
Compatible Hardware Systems OPAL-100 Series Analyzers | OndaVia Analysis System

Instrument Platform Order SKU Validated Range Primary Field Application
OPAL Benchtop OV-OP-B036-LPM 1 – 10 ppm Trace methanol detection in gas plant condensate and water discharge
OPAL Benchtop OV-OP-B036-PPM 5 – 100 ppm Produced water tracking, hydrate inhibitor partitioning, and chemical injection
OPAL Benchtop OV-OP-B036-HPT 50 – 100 % Virgin methanol delivery verification and high-strength inhibitor QA/QC
OndaVia Analysis System OV-PP-B036-LPM 1 – 10 ppm OndaVia Analysis System trace methanol monitoring
OndaVia Analysis System OV-PP-B036-PPM 5 – 100 ppm OndaVia Analysis System hydrate inhibitor tracking
OndaVia Analysis System OV-PP-B036-HPT 50 – 100 % OndaVia Analysis System solvent strength and chemical receipt testing

Kit Contents & Scope of Supply

  • 10× Methanol (B036) Analysis Cartridges

Additional information

Weight 0.1 lbs
Dimensions 14 × 14 × 4 in
Brand

OndaVia, Opal

Range

HPT (50-100%), LPM (1-10-ppm), PPM (5-100-ppm)